How to Prepare Samples:
|
Step 1
|
Prepare up to 2 mg total protein sample for loading.
Prepare a Minigel or standard SDS-PAGE gel using 1 mm thickness spacers
and a prep-comb (with 1 big flat tooth) to
make a wide flat well, deep enough to meet the loading volume.
|
|
Step 2
|
Run the gel as regular SDS-PAGE procedure to separate the protein of interest.
|
|
Step 3
|
Stain the gel with coomassie blue.
Destain the gel and identify the protein band of interest.
|
|
Step 4
|
Cut the band of interest using the whole width of the gel
|
|
Step 5
|
Transfer the gel strip with protein band into a tube, and send the sample for antibody production. The sample can be sent at room temperature.
|